[email protected] + 91 22 22037467 / 22037465

Boiler Water Treatment Chemicals

Novachem Hardness Control

NOVA HARDNESS CONTROL is a dry powdered phosphate based treatment used to precipitate calcium hardness as a non- adherent sludge. It is a free-flowing white powder which is readily soluble in water.

Purpose :

When NOVACHEM HARDNESS CONTROL is added to the boiler water under proper conditions it supplies the necessary phosphate to chemically react with calcium hardness to prevent the formation calcium carbonate, sulphate and/or silicate scales. The reaction between calcium and phosphate produces a finely divided non adherent sludge (calcium phosphate) which remains suspended in the boiler water and removed through blowdown.

Advantages :

1. Scale problems eliminated. Sludge problems greatly reduced.
2. Easily dissolves in water to prepare feed solutions.
3. 100 % active material.
4. Dry product minimizes shipping cost.
5. Feed solutions up to one pound per gallon possible.

Feed Requirements :

NOVACHEM HARDNESS CONTROL is used in controlled amount so as to maintain a free phosphate residual in the boiler water. The control limits for phosphate normally are in the 20 to 60 ppm range. Exact parameters will be sent by our representative for your installation. The feed rate will vary depending upon the calcium hardness of the make-up water.

Method Of Feeding :

Dissolve in warm water and slug feed intermittently to the boiler feed water line or with a continuous feed pump to the boiler. Novachem Hardness Control can be mixed with other treatment chemicals used for internal treatment. Material of construction of the feed equipment are not critical, but dissimilar metals should be avoided.

Storage & Handling :

Store in a dry place, keep container closed when not in use. Avoid contact with skin. Wash with large quantities of water. In case of contact with eyes, treat with large volumes of water and see a physician.

Dosage Chart For Nova Hardness Control

1. Find your boiler operating pressure on left.
2. Find your phosphate test results as ppm PO4 across the top.
3. Read across from your operating pressure until you reach the column with your ppmPO4 results. This square will give you the correct dosage of Nova Hardness Control to reach the correct protection for your boiler. ............................................Dosage table in grams/ton

Boiler type........................................ Test Results phosphate as ppm PO4
0-10......... 10-20.......... 20-40............40-60...........60-80............. Over 80
Below 400 psi......... 90 .............70............... 40................ 10........ Satisfactory......... Blow down (28 bar)
400-600 psi ............50............... 30........ Satisfactory.... No dose.... High blow...........Blow down
28-42 bar)
600-800 psi............ 60............... 20........ Satisfactory..... No dose.... High blow.......... Blow down (42-59 bar)
Double pressure..... 40............... 30........ Satisfactory.... Satisfactory.... No dose........ Blow down primary system
Double pressure..... 80 ...............60................ 30........... Satisfactory..... No dose....... Blow down primary system .