[email protected] + 91 22 22037467 / 22037465

Cooling Water Treatment

Novachem 2000

NOVACHEM 2000 is the ideal corrosion inhibitor for closed heating or cooling systems, such as diesel engines, compressors, process cooling systems, etc. NOVACHEM 2000 is a non-chromate, non-phosphate, free flowing liquid that is extremely effective for controlling corrosion while avoiding the pollution and toxicity problems associated with chromate based inhibitors.

Advantages :

* Controls attack on piping, valves, pumps and heat exchangers by producing a protective film on all exposed metal surfaces - iron, steel, copper, copper alloys, aluminium and brass.
* Inherent Buffering agent automatically adjusts pH at the preferred level.
* Does not adversely affect pump glands, rubber hose, water seals, and valve packings.
* Prevents deposition of copper on ferrous surfaces by "tying up" any copper which might be introduced. This eliminates the possibility of attack caused when copper deposits on steel to form galvanic cells or corrosion couples.
* Compatible with alcohol and glycol base antifreezes.
* Does not contain chromate or produce colour in the treated water, thereby eliminating the possibility of stain.

Application :

Feed the NOVACHEM 2000 into any convenient point in the system with a chemical proportioning pump or slug feed by using an appropriate by-pass feeder.

Dosage :

Concentration level in the system must not be allowed to drop below 1500 ppm as nitrite (NO). For economical reasons try to maintain nitrite Level between 1500 ppm to 2000 ppm although higher nitrite levels will not cause operating difficulties. Nitrite level is obtained by using a simple colourimetric test for nitrite.

Dosage Table :

Nitrite reading as ppm NO2 NOVACHEM 2000 required as ltrs per 1000 ltrs of water in system
0 – 300…………. 14 Ltrs.
300 – 600………. 10 Ltrs.
600 – 900………… 8 Ltrs.
900 – 1200………. 5 Ltrs.
1200 – 1500……… 2 Ltrs
over – 1500………. NONE

For example in untreated systems add 8.0 ltrs. of NOVACHEM 2000 for every 1000 litres of water in the system and check (NO2) level with test kit after 4 hours. Adjust dosage as required after regular intervals.

Testing (Remarks) :

* Use only cooling and feed water according to the requirements of the motor manufacturer.
* Check pH of cooling water regularly - pH should be maintained between 7.5 and 9.5.
* If the cooling water contains anti-freeze the above described test is not reliable.
* To check for hardness, chlorides, and pH, refer to the NOVA Technical Date sheet for Cooling Water tests.

Caution :

Wear rubber gloves and avoid contact with skin and eyes when handling NOVACHEM 2000. In case of contact, immediately flush skin and eyes with water for 15 minutes. Get medical attention.